M.O.L.E. EV12

M.O.L.E. EV12 Operation
M.O.L.E. EV12 Logo
M.O.L.E. EV12 Logo

TOUCH CONTROL TWELVE MEASUREMENT THERMAL PROFILER

M.O.L.E.ยฎ EV12 thermal profiler delivers the power and immediacy of touchscreen thermal profiling control in a 12-channel data logger. Bridging the gap between six- and 20-channel M.O.L.E. EV models, the M.O.L.E. EV12 addresses specific applications that require nine to twelve thermal measurements. M.O.L.E. EV12โ€™s full-color touch display enables process calculation templates, profiles, and pass/fail results to be observed directly on the device. No PC download is required for profile viewing. All M.O.L.E. EV-series profilers have Bluetoothยฎ wireless connectivity, deliver higher sampling rates with greater accuracy, and support multiple thermocouple types.

Key Features

SIMPLE AND IMMEDIATE STATUS CONFIRMATION

โ— On-screen instrument status display:
ยป Live temperature readings
ยป Thermal profile
ยป KPI table


PREVENTATIVE MAINTENANCE

โ— Built-in calibration reminders
โ— Battery life/charge indicators
โ— Memory status indicator


FLEXIBILITY

โ— 12 thermocouple inputs organized into two groups of six channels
โ— Uses ECD micro-connectors
โ— Supports multiple thermocouple types

SPEED

โ— Sampling at up to 50 samples per second


EASE OF USE

โ— USB-C communications and charging
โ— Two-button control (on/off and record)


WIRELESS CAPABILITY

โ— Wireless operation with Class 1 Bluetoothยฎ RF 5.1 LE


OPERATIONAL ROBUSTNESS

โ— High-capacity, off-the-shelf LiPo battery
โ— Auto shutdown protection for over temp conditions
โ— Watchdog timer-monitored firmware control
โ— ESD-protected inputs
โ— Non-volatile profile memory

M.O.L.E. EV12 System Kit

What’s in the Kit


STANDARD THERMAL PROFILER KIT

ECD P/N: E63-3812-00

  • M.O.L.E. EV12 Profiler (w/integrated battery)
  • 395L stainless steel Thermal Barrier
  • 395L Yellow Jacket Thermal Barrier Cover
  • Two sets of six glass color-indexed 36-gauge thermocouples
  • M.O.L.E.ยฎ MAP Software
  • PC USB-C Cable (Set-up & Download)
  • Universal Power Pack Charger
  • Quick Reference Guide
  • Carrying Case
  • Calibration certificate from ECD’s ISO 17025-accredited lab
  • 2 Year Warranty

Specifications


Full Specifications (Click Here)

DISPLAY:

  • PS TFT Display
  • 240 x 400 Dot Matrix
  • High Brightness LED Backlight
  • Any Angle Viewing Direction

THERMOCOUPLE SENSORS (UP TO 12):


  • ECD micro-thermocouples: Type K*, T, J, E, N, R, S & B
  • %RH: ECD VaporWATCHยฎ RH Sensor

DATA ACQUISITION:

  • Sampling Interval: 50 samples/second to 10 minutes/sample
  • Data points: 16 million or 200 data runs (whichever comes first)
  • Accuracy: +/- 0.5ยฐC (0.9ยฐF)
  • Resolution: 0.0056ยฐC (0.01ยฐF)*
  • Noise Rejection: 50-60 hrz*
  • Measurement range: -200ยฐC to 1,200ยฐC (-328ยฐF to 2,192ยฐF)

*>= 0.05 seconds/sample


POWER:

  • Battery: LiPo (Lithium Polymer ion) – Rechargeable, 1100mAh
  • Charge Protection: optimized for lithium polymer
  • Charge time: Full – < 4 hours
  • Charge runtime: Full – 6 to 8 Hours
  • Battery Life: 300-400 charging cycles or 3 years (Minimum)
  • Charger input current: 60 ma via USB Interface

PHYSICAL:

  • Dimensions (L x W x H):
    • Profiler: 350.8mm (13.81โ€) x 89mm (3.5โ€) x 9.41mm (0.37โ€)
    • Barrier: 412.8mm (16.25โ€) x 104mm (4.1โ€) x 26.9mm (1.06โ€)
    • Yellow Jacket: 423.4mm (16.7โ€) x 115mm (4.53โ€) x 32.5 (1.28โ€)
  • Weight:
    • Profiler: 0.386 kg (13.6 oz)
    • Barrier: 1.202 kg (2.65 lb)
    • Yellow Jacket: 1.113 kg (4.0 oz)
  • Operational range (Profiler): -40ยฐC to +80ยฐC (-40ยฐF to 176ยฐF)
  • Humidity: 0-85% RH (Non Condensing)

COMMUNICATIONS:

  • Interface: USB 2.0 Compliant (charge; upload; download)
  • Cable: USB Type A to USB-C, 1m (3โ€™)

COMPLIANCE:


PATENT:

  • Patent No. 7,653,502

WARRANTY:

  • 2 years parts and labor

Request Form


Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

sales@ecd.com

support@ecd.com

1.503.659.6100

1.800.323.4548

ECD Partner Network

ECD Partner Network – NA

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)

Product Support


M.O.L.E. EV12

M.O.L.E. EV6

M.O.L.E. EV6 Operation
MOLE EV6 Logo
MOLE EV6 Logo

AN EVOLUTION IN THERMAL PROFILING

With a revolutionary new design, M.O.L.E.ยฎ EV6 brings deep data collection and touch screen convenience to thermal profiling. The traveling thermal profiler allows configuration, measurement and data analysis right on the device โ€“ providing immediate actionable information, saving time and reducing the requirement for intensive operator training. Using a familiar smartphone-like capacitive touch screen, users now have shop floor data literally at their fingertips. The six-channel M.O.L.E. EV6 integrates with all ECD RIDERโ„ข machine quality management technologies for a truly scalable approach, made easier with visual, touch screen control.

Key Features

SIMPLE AND IMMEDIATE STATUS CONFIRMATION

โ— On-screen instrument status display:
ยป Live temperature readings
ยป Thermal profile
ยป KPI table


PREVENTATIVE MAINTENANCE

โ— Built-in calibration reminders
โ— Battery life/charge indicators
โ— Memory status indicator


FLEXIBILITY

โ— Supports multiple thermocouple types

SPEED

โ— Sampling at up to 100 samples per second


EASE OF USE

โ— USB-C communications and charging
โ— Two-button control (on/off and record)


OPERATIONAL ROBUSTNESS

โ— High-capacity, off-the-shelf Lipo battery
โ— Auto shutdown protection for over temp conditions
โ— Programmable to conserve battery life
โ— Watchdog timer-monitored firmware control
โ— ESD-protected inputs
โ— Non-volatile profile memory

MOLE EV6 System Kit

What’s in the Kit


STANDARD THERMAL PROFILER KIT

ECD P/N: E61-3806-00

  • M.O.L.E. EV6 Profiler (w/integrated battery)
  • 260L stainless steel Thermal Barrier
  • 260L Yellow Jacket Thermal Barrier Cover
  • Glass set of 6 Color-Indexed 36-gauge Thermocouples
  • M.O.L.E.ยฎ MAP Software
  • PC USB C Cable (Set-up & Download)
  • Universal Power Pack Charger
  • Quick Reference Guide
  • Carrying Case
  • Calibration Certificate from ECD’s ISO 17025 accredited lab

Specifications


Full Specifications (Click Here)

DISPLAY:

  • PS TFT Display
  • 240 x 400 Dot Matrix
  • High Brightness LED Backlight
  • Any Angle Viewing Direction

THERMOCOUPLE SENSORS (UP TO 6):


  • ECD Micro-Thermocouples: Type K*, T, J, E, N, R, S & B
  • %RH: ECD VaporWATCHยฎ RH Sensor

DATA ACQUISITION:

  • Sampling Interval: 100 samples/second to 10 minutes/sample
  • Data points: 16 million (2.6 million at 6 channels) or 200 data runs (whichever comes first)
  • Accuracy: +/- 0.5ยฐC (0.9ยฐF)
  • Resolution: 0.0056ยฐC (0.01ยฐF)*
  • Noise Rejection: 50-60 hrz*
  • Measurement range: -200ยฐC to 1,200ยฐC (-328ยฐF to 2,192ยฐF)

*>= 0.05 seconds/sample


POWER:

  • Battery: Lipo (Lithium Polymer ion) – Rechargeable, 1100mAh
  • Charge Protection: optimized for lithium polymer
  • Charge time: Full – < 4 hours
  • Charge runtime: Full – 6 to 8 Hours
  • Battery Life: 300-400 charging cycles or 3 years (Minimum)
  • Charger input current: 60 ma via USB Interface

PHYSICAL:

  • Dimensions (L x W x H):
    • Profiler: 152.4mm (6โ€) x 89mm (3.5โ€) x 9.41mm (0.37โ€)
    • Barrier: 253.9mm (10.0โ€) x 104mm (4.1โ€) x 26.9mm (1.06โ€)
    • Yellow Jacket: 264.6mm (10.4โ€) x 115mm (4.53โ€) x 32.5 (1.28โ€)
  • Weight:
    • Profiler: 0.204 kg (7.2 oz)
    • Barrier: 0.861 kg (30.4 oz)
    • Yellow Jacket: 0.07 kg (2.4 oz)
  • Operational range (Profiler): -40ยฐC to +80ยฐC (-40ยฐF to 176ยฐF)
  • Humidity: 0-85% RH (Non Condensing)

COMMUNICATIONS:

  • Interface: USB 2.0 Compliant (charge; upload; download)
  • Cable: USB Type A to USB-C, 1m (3โ€™)

COMPLIANCE:


PATENT:

  • Patent No. 7,653,502

WARRANTY:

  • 2 years parts and labor

Request Form


Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

sales@ecd.com

support@ecd.com

1.503.659.6100

1.800.323.4548

ECD Partner Network

ECD Partner Network – NA

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)

Product Support


M.O.L.E. EV6

Download

PRODUCT DOWNLOADS

PDF

INDUSTRY RESOURCES

Thermal Profiling Course – Electronics

Learn why thermal profiling in electronics is important.

Accurate measurement of any process is the key to success. In electronics, thermal profiling is the only way to fully understand what is happening in the reflow soldering process.

This course will:

  • Review the basics of thermal profiling
  • Explain why profiling is important
  • Provide information about what could happen if profiling is not regularly employed

What to Expect From This Course:

  • 5 Modules of Succinct Information: ECDโ€™s thermal profiling course #1 has 5 Modules to introduce thermal profiling basics and fine-tune your understanding. Intentionally, the content has been honed to present the most important aspects needed for thermal profiling based on the feedback participants supplied. Thank you for your contribution to making this course a success. We hope you enjoy it.
  • Module Links: Links to progress to the next step are provided at the bottom of each Module, so you can choose to move through the course at your own pace. We know youโ€™re busy so when you sign up links to each Module will be emailed to you so you can resume where you have left off.
  • We Welcome Your Feedback: At the end of the course we encourage you to complete a course survey. Your feedback will help to improve this course for others in the future.

Let us help you (thermal) profile better! Get started now!

BEGIN TODAY!

By signing up, you will be taken directly to our online course where you can begin immediately.

SuperM.O.L.E. Gold 2

Looking for a 6-channel thermal profiler?

The popular SuperM.O.L.E. Gold 2 has been retired, but we have something better in its place!

Check out the 6-channel touchscreen M.O.L.E.โ„ข EV6.

Key Features


LEDs Show T/C Readiness

โ— No wasted data runs

โ— At a glance open thermocouple indicators


PROTECT YOUR TIME AND PROFILER

โ— Know critical systems are โ€œGOโ€ before you thermal profile


OK BUTTON

โ— Operator gets GO/NO-GO
decision control

โ— Improves productivity

โ— Saves Time

NEVER LOSE A THERMAL PROFILE

โ— Separate On/Off and
Record buttons

โ— Prevents lost profiles


1.5 MILLION DATA POINT MEMORY

โ— 96 thermal profile storage lets you download on demand


EASY TO USE

โ— Built-in Wireless Option

โ— USB enabled Fast Upload,
Download or Charge

What’s in the Kit


STANDARD THERMAL PROFILER KIT

  • SuperM.O.L.E. Gold 2, 6-Channel Profiler, RoHS Compliant
  • 1.0″ Uni-Barrier stainless steel thermal barrier
  • Yellow Jacket Thermal Barrier Cover
  • Glass set of 6 Color-Indexed 36-gauge Thermocouples
  • M.O.L.E.โ„ข MAP Software
  • PC USB 2.0 Cable (Communication and Charging)
  • Universal AC Power Pack Battery Charger
  • Quick Reference Guide
  • Carrying Case
  • Calibration Certificate from ECD’s ISO 17025 accredited lab

Specifications


Full Specifications (Click to View)

THERMOCOUPLE SENSORS:

  • Up to 6 Type K* (ECD M.O.L.E.โ„ข Micro connector)

DATA ACQUISITION:

  • Sampling Interval: 0.1 seconds to 24 hours
  • Data points: 250,000 for all 6 channels
  • Data runs stored: 96 (Standard Thermal Profiles)
  • Accuracy: +/- 1ยฐC (1.8ยฐF)
  • Resolution: 0.056ยฐC (0.1ยฐF)
  • Measurement range: -200ยฐC to 1271ยฐC (-328ยฐF to 2320ยฐF)

POWER:

  • Battery: Lithium Polymer – Rechargeable, 340mAh
  • Charge Protection: optimized for lithium polymer
  • Charge time:
    • Full: 8 hours
    • Partial: 15 min. charge allows one 10min. data run
  • Charge Capacity:
    • 50 ten minute data runs*
  • Battery Life: 300-400 charging cycles or 3 years (Minimum)
  • Charger input current: 175 ma via USB Interface
  • Operating Range: 4.2V to 3.2V

*New, fully charged Power Pack.


PHYSICAL:

  • Dimensions (L x W x H):
    • Profiler: 152.4mm (6โ€) x 89mm (3.5โ€) x 9.41mm (0.37โ€)
    • Barrier: 269.7mm (10.62โ€) x 104mm (4.1โ€) x 26.9mm (1.06โ€)
    • Yellow Jacket: 286.5mm (11.28โ€) x 115mm (4.53โ€) x 32.5 (1.28โ€)
  • Weight:
    • Profiler: .204 kg (7.2 oz)
    • Barrier: .861 kg (30.4 oz)
    • Yellow Jacket: 0.07 kg (2.4 oz)
  • Operational range (Profiler): -40ยฐC to +85ยฐC (-40ยฐF to 185ยฐF)
  • Humidity: 0-85% RH (Non Condensing)

COMMUNICATIONS:

  • Interface: USB Compliant (charge; upload; download)
  • Cable: USB Type A, Male-to-Mini B, 5 pin Male, 1m (3โ€™)

COMPLIANCE:


PATENT:

  • Patent No. 7,653,502

WARRANTY:

  • 2 years parts and labor

Request Form


Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

sales@ecd.com

support@ecd.com

1.503.659.6100

1.800.323.4548

ECD Partner Network

ECD Partner Network – NA

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)

Product Support


SuperM.O.L.E. Gold 2

Essential Tools for High-Accuracy Thermal Profiling

Cover - Industry Papers Electronics
Whitepaper - Essential Tools for High-Accuracy Thermal Profiling

OVERVIEW

Understanding process heating and heating transfer mediums determine the needed type and size of thermocouple sensor and thermal protecting barrier. Modes of heat transfer, temperature ranges, and duration are all critical variables when measuring temperature.

KEY LEARNING POINTS:

  • You will learn the different wire insulation types and temperature ranges
  • When you might choose one type over the other
  • How thermal conductivity (thermal resistance) affect survival time
  • Proper energy dissipation between profile runs
DOWNLOAD THE WHITEPAPER!

Please use the form to download the document.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Industry*
(Select all that apply)

ECD Insider*

Yes, I understand when submitting this form, I’m subscribing to become an ECD Insider and enjoy exclusive benefits and updates. Donโ€™t worry, you can always unsubscribe at any time.

This field is hidden when viewing the form
This field is hidden when viewing the form

Webinar Signup — Barriers & Thermocouple Attachments

ESSENTIAL TOOLS FOR HIGH-ACCURACY THERMAL PROFILING

Watch On-Demand
Electronics - Thermocouple Attachment

OVERVIEW

Understanding process heating and heating transfer mediums determine the needed type and size of thermocouple sensor and thermal protecting barrier.  Modes of heat transfer, temperature ranges, and duration are all critical variables when measuring temperature.

KEY POINTS:

  • Learn how to select the proper thermocouples for the job
  • Understand the a-b-cโ€™s of thermocouple attachment (there are some tricks of the trade!)
  • Get the details about what a thermal barrier does and does not do and why certain features are important
WATCH TODAY!

By signing up, you will be taken directly to our on-demand webinar where you can view the webinar immediately.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Industry*
(Select all that apply)

ECD Insider*
Yes, I understand that when submitting this form I am also becoming an ECD Insider. Don’t worry, if you change your mind, you can unsubscribe at any time.

This field is hidden when viewing the form
This field is hidden when viewing the form

Webinar On Demand — Barriers & Thermocouple Attachments

Cover - Webinar Electronics

THANKS FOR YOUR INTEREST!

The on-demand webinar is below and available to you for viewing at your convenience.


QUESTIONS?

Do you have any further questions?

Thermal Profiling Course

Learn why thermal profiling in electronics is important.

Accurate measurement of any process is the key to success. In electronics, thermal profiling is the only way to fully understand what is happening in the reflow soldering process.

This course will provide you with…

  • Review the basics of thermal profiling
  • Why profiling is important
  • What could happen if profiling is not regularly employed

22 Simple Tips for Running Successful Thermal Profiles

Cover Industry Papers - Electronics
Whitepaper - 22 Simple Tips for Running Successful Thermal Profiles

OVERVIEW

This document provides an easy stepโ€byโ€step guide to help deliver good thermal profiles. Even for a seasoned operator or engineer, itโ€™s easy to forget the little things that can impact the process. Take the time to engage in this quick read; these tips can help you.

KEY LEARNING POINTS:

  • Avoid reโ€running profiles or rebuilding boards due to damage during profiling.
  • Eliminate practices that may impact the longโ€term quality and reliability of PCB assemblies.
  • Protect operators and engineers from injury.
  • Maintain good practices for thorough, accurate profiling.
DOWNLOAD THE PAPER!

Please use the form to download the document.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Industry*
(Select all that apply)

ECD Insider*

Yes, I understand when submitting this form, I’m subscribing to become an ECD Insider and enjoy exclusive benefits and updates. Donโ€™t worry, you can always unsubscribe at any time.

This field is hidden when viewing the form
This field is hidden when viewing the form

Thermal Profiling – Integral to a Process in Control

Cover Industry Papers - Electronics
Whitepaper - Thermal Profiling: Integral to a Process in Control

OVERVIEW

The complexity of todayโ€™s PCB assemblies with higher densities requires a robust thermal process to ensure high yield manufacturing.  Analyzing and recording the thermal process through thermal profiling is essential to a well-documented operation in control.

KEY LEARNING POINTS:

  • Thermal Profiling is Critical to Good Process Control
  • How to Successfully Profile the PCB or the Reflow Oven
  • Analyzing the Profile Results: What do they mean?
  • Why Traceability is Essential for Compliance and Liability
DOWNLOAD THE PAPER!

Please use the form to download the document.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Industry*
(Select all that apply)

ECD Insider*

Yes, I understand when submitting this form, I’m subscribing to become an ECD Insider and enjoy exclusive benefits and updates. Donโ€™t worry, you can always unsubscribe at any time.

This field is hidden when viewing the form
This field is hidden when viewing the form

Oven vs. Product Profiling

Cover Industry Papers - Electronics
Whitepaper - Oven vs. Product Profiling

OVERVIEW

A simple alternative to conventional โ€œgolden boardโ€ profiling offers quality assurance and repeatability for high-mix, low-volume manufacturing operations.

KEY LEARNING POINTS:

  • A three-channel test vehicle can be used as a surrogate to represent a profile of a populated product.
  • By using a surrogate test vehicle, you can save resources and improve product quality and repeatability.
  • By profiling the oven instead of the product, tremendous production benefits are realized.
DOWNLOAD THE PAPER!

Please use the form to download the document.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Industry*
(Select all that apply)

ECD Insider*

Yes, I understand when submitting this form, I’m subscribing to become an ECD Insider and enjoy exclusive benefits and updates. Donโ€™t worry, you can always unsubscribe at any time.

This field is hidden when viewing the form