REFLOW PROCESS VERIFICATION… MADE EASY!
ECD, the world leader in thermal profiling solutions, introduces an easy to use yet powerful tool for verifying a production reflow oven – OvenCHECKER™.
Built around ECD’s award winning V-M.O.L.E.™ Thermal Profiler, the OvenCHECKER system comes complete with the profiler, thermal barrier, pallet with 3 surface sensors and M.O.L.E. MAP software, making it a complete solution for reflow oven verification.

Key Features
EASY TO USE
✔ 1: SPECIFY
Engineer sets specifications in MAP software for profile:
- Ramp
- Soak
- TAL
- Peak
✔ 2: RUN
Operator sends the
OvenCHECKER™
through the oven.
✔ 3: VERIFY
Operator presses
the “OK” button.
- Green = Go
- Red = Stop
V-M.O.L.E.™ Thermal Profiler
Innovative “OK Button” feature, indicating Go/No-Go (relative to your profile specifications) at the touch of a button
3 Surface Sensors
Similar in profile to FR4 PCB
Thermal Barrier
Thermal protective barrier for the V-M.O.L.E.®. Removable so it can be used for standard Thermal Profiling.

What’s in the Kit
STANDARD KIT DESCRIPTION
ECD P/N: E49-2435-02
- OvenCHECKER™
- 12 in. [305 mm] wide pallet (Includes 3 sensors & Thermal Barrier)
- V-M.O.L.E™ Thermal Profiler
- With USB rechargeable battery
- M.O.L.E.™ MAP Software
- PC USB 2.0 Cable
- Set-up, Download & Charging
- Quick Reference Guide
- Carrying Case
- Calibration Certificate from ECD’s ISO 17025 accredited lab
Specifications
Full Specifications (Click to View):
PHYSICAL – OvenCHECKER™:
- Length (Pallet): 15.0in. (38.1cm)
- Height (Thermal Barrier): 2.54cm (1.0in.)
- 17.8mm (0.7”) above conveyor chain
- 7.6mm (0.3”) below conveyor chain
- Width (Pallet): 30.5cm (12in.)
- Weight (Pallet): 1656 grams (3.65 lbs.)
- Pallet Surface Sensor Thickness: 1.58mm (0.062in.)
- Max. Operational Temperature (Pallet): 300°C (572°F)
- Max. Operational Temperature (Thermal Barrier):
- 200°C (392.0°F) for 10 min.
- 150°C (302.0°F) for 15.8 min.
PHYSICAL – V-M.O.L.E.™:
- Dimensions (L x W x H):
- 145mm (5.7”) x 64mm (2.5”) x 7.62mm (.3”)
- Weight:
- 0.068 kg (2.4 oz)
- Operational range (Profiler): -40°C to +85°C (-40°F to 185°F)
- Humidity: 0-85% RH (Non Condensing)
DATA ACQUISITION – V-M.O.L.E.™:
- Sampling Interval: 0.1 seconds to 24 hours
- Data points: 500,000 total for 3 channels
- Data runs stored: 96 (Standard Thermal Profiles)
- Accuracy: +/- 1°C (1.8°F)
- Resolution: 0.056°C (0.1°F)
- Measurement range: -200°C to 1271°C (-328°F to 2320°F)
COMPLIANCE:


WARRANTY:
- 1 year parts and labor
Request Form
Contact Us
ECD NORTH AMERICA (US, CANADA)
Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.
LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
Houston, TX U.S.A. Office
EMEA (EUROPE, MIDDLE EAST, AFRICA)
UK Office
APAC (ASIA-PACIFIC, CHINA, INDIA)
Singapore Office
Product Support
OvenCHECKER

PRODUCT DOWNLOADS
- Datasheet: Letter | A4 | Spanish | Chinese
- Quick Reference Guide
- M.O.L.E.™ MAP Software
- ECD Product Catalog: Digital | PDF