SelectiveRIDER

SelectiveRIDER - Process Precision For Selective Solder Repeatability
SelectiveRIDER Logo

PROCESS PRECISION FOR SELECTIVE SOLDER REPEATABILITY

The SelectiveRIDER® is a measurement pallet designed to capture parameters from the selective solder process and collect machine data for repeatability. It uses a 6-Channel ECD M.O.L.E.® thermal profiler profiler as the data collection device, and a dedicated environment in MAP software for analysis and SPC. It captures: fountain height, fountain X/Y accuracy, fountain diameter, solder temperature, maximum preheat, Delta T at contact, Flux penetration, and Fluxer X/Y accuracy.

Key Features


DYNAMIC X/Y SENSOR

Measures both X and Y position from target center​ in addition to fountain diameter while touching the bottom of the pallet.


MINI Fluxometer™

Included with the kit are two test mesh types; V-Gauge (Vernier) and UP (Uniformity & Penetration) along with three types of test paper.

V-Gauge Mesh Measures:

  • Dispense accuracy (X and Y)
  • Indicates blocked/unprimed spray head
  • Confirms dot size
  • Illustrates under/overspray

UP Mesh Measures:

  • Accuracy of flux application patterns
    and uniformity
  • Flux hole penetration

RIDER INDICATOR

The Rider LED Indicates when SuperM.O.L.E.™ Gold 2 is connected to a SelectiveRIDER. And when connected to a M.O.L.E.® EV6, a “RIDER“ symbol appears on the display. This also automatically sets the M.O.L.E.’s configuration.


HEIGHT SENSOR

Measures fountain height as referenced from the bottom of the pallet.


THERMAL BARRIER

Easy docking and automatic configuration through built-in barrier technology.

SelectiveRIDER System Kit

What’s in the Kit


STANDARD KIT

ECD P/N: E60-7353-05

  • SelectiveRIDER Pallet
  • Dynamic X/Y Sensor
  • Mini Fluxometer (V-Gauge & UP)
  • Test Paper (IPA, Neutral PH & Low PH)
  • M.O.L.E.® MAP Software
  • Quick Reference Guide
  • Carrying Case
  • 1-year warranty on materials and workmanship

Specifications


Full Specifications (Click to View):

THERMOCOUPLE SENSORS:

  1. Max Pre-heat / Delta T​
  2. Fountain Temperature​
  3. Fountain X/Y Position / Diameter​
  4. Fountain Height
  5. Dwell Time
  6. Flux Deposition / Uniformity
  7. Specs

MEASUREMENT ACCURACY:

Dynamic:

X/Y Fountain Position Accuracy:​

  • Range: 0 mm – 5.5 mm in ±X and ±Y Coordinates​
  • Accuracy: ±0.5 mm​
  • Resolution: 0.1 mm

Fountain Diameter:

  • Range: 3 mm to 12 mm​
  • Accuracy: ± 0.5 mm​
  • Resolution: 0.1 mm​

Fountain Height​:

  • Range: 0 mm to 6 mm​
  • Accuracy: ± 0.5 mm​
  • Resolution: 0.5 mm

Dwell Time​:

  • Accuracy: ±0.01 Sec​
  • Resolution 0.1 Sec​

Thermal:​

Top Side Max Preheat​
Top Side Delta T​
Fountain Temp

  • Accuracy:✹ ±1 °C​
  • Resolution: 0.1 °C

Type K: Special Limits of error ±1.1 or ±0.004*T per ASTM E230/E230M-12, IEC 60584:2013 and ISA–MC96.1–1982.


PHYSICAL:

  • Length: 300 mm [11.8 in.]
  • Width: 200 mm [7.87 in.]
  • Height: 35.4 mm [1.39 in.]
  • Weight: 1.72 kg [3.78 lbs]
  • Max. Operational Temperature (Pallet): 300°C [572°F]

COMPLIANCE:


WARRANTY:

  • 1 year parts and labor

Request Form


Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)

Product Support


SelectiveRIDER