V-M.O.L.E. 2 Solar

Solar Cell Manufacturing
V-M.O.L.E. 2 Logo

Easy-to-use ~ Value-priced

ECD’s V-M.O.L.E.™ 2 Solar Profiling System is designed to provide assurance that these key process parameters are met quickly and easily.

  • Temperature Ramp Rate
  • Hold Time (Dry Time)
  • Time Above Temperature
  • Peak Temperature
  • Cooling Rate

Key Features


PROTECT YOUR TIME AND PROFILER

● Indicators identify if critical systems are “GO” before profiling:
» Internal battery voltage is low
» Internal temp is at or above a threshold
» Memory is full
» All channels are OFF


FLEXIBILITY

● 4 thermocouple inputs
● Uses standard, mini thermocouple connectors
● Multiple thermocouple types supported

PROFILE VERIFICATION

● 4 Channels, all you need to run a profile verification


SPEED

● Sampling at up to 100 samples per second
● Higher sampling rates with higher accuracy


BUILT TO LAST

● High-capacity, off-the-shelf LiPo battery
● Automatic shutdown if internal temperature is too high
● ESD-protected inputs

EASE OF USE

● USB-C communications and charging
● Two-button control (on/off and record)


SOLAR CELL METALLIZATION PROCESS

Solar Cell Metalization Process

The typical process is short in time (40-60 seconds) ramping quickly to Peak.

V-M.O.L.E. 2 Solar System Kit

What’s in the Kit


STANDARD KIT

ECD P/N: E63-0765-00

  • V-M.O.L.E. 2 thermal profiler
  • Stainless steel thermal barrier (reflective finish | 18mm (0.7”) thick)
  • Set of 4 high-temp stainless steel thermocouples
  • M.O.L.E.® MAP Software
  • PC USB 2.0 Cable (Communication and Charging)
  • Universal AC Power Pack Battery Charger
  • Carrying Case
  • Calibration Certificate from ECD’s ISO 17025 accredited lab

Specifications


Full Specifications (Click to View)

THERMOCOUPLE SENSORS (4):


  • Standard mini-thermocouples: Type K*, T, J, E, N, R, S & B
  • %RH: ECD VaporWATCH® RH Sensor

DATA ACQUISITION:

  • Sampling Interval: 100 samples/second to 10 minutes/sample
  • Data points: 16 million (2.6 million at 6 channels) or 200 data runs (whichever comes first)
  • Accuracy: +/- 1°C (1.8°F)
  • Resolution: 0.0056°C (0.01°F)*
  • Noise Rejection: 50-60 hrz*
  • Measurement range: -200°C to 1,200°C (-328°F to 2,192°F)

*>= 0.05 seconds/sample


POWER:

  • Battery: LiPo (Lithium Polymer ion) – Rechargeable, 1100mAh
  • Charge Protection: optimized for lithium polymer
  • Charge time: Full – < 4 hours
  • Charge runtime: Full – 6 to 8 Hours
  • Battery Life: 300-400 charging cycles or 3 years (Minimum)
  • Charger input current: 60 ma via USB Interface

PHYSICAL:

  • Dimensions (L x W x H):
    • Profiler: 165.1mm (6.5”) x 89mm (3.5”) x 9.41mm (0.37”)
    • 237mm (9.3”) x 97.8mm (3.85”) x 17.8mm (0.70”)
  • Weight:
    • Profiler: 0.182 kg (6.4 oz)
    • Barrier: 0.431 kg (15.2 oz)
  • Operational range (Profiler): -40°C to +80°C (-40°F to 176°F)
  • Humidity: 0-85% RH (Non Condensing)

COMMUNICATIONS:

  • Interface: USB 2.0 Compliant (charge; upload; download)
  • Cable: USB Type A to USB-C, 1m (3’)

COMPLIANCE:


PATENT:

  • Patent No. 7,653,502

WARRANTY:

  • 2 years parts and labor

Request Form


Contact Us


ECD NORTH AMERICA (US, CANADA)

Worldwide Headquarters
4287-B SE International Way
Milwaukie, Oregon 97222-8825 U.S.A.

LATAM (MEXICO, CENTRAL, SOUTH AMERICA)
EMEA (EUROPE, MIDDLE EAST, AFRICA)
APAC (ASIA-PACIFIC, CHINA, INDIA)