<< Click to Display Table of Contents >> Navigation: »No topics above this level« 7.0 Network Dashboard |
.png)
| 1) | Data Graph: |
oCrosshair - The Data Graph displays a line connecting the points with their corresponding axis.
oRange Selector: The range selector is a tool for selecting ranges to display within the chart. It provides buttons to select preconfigured ranges in the chart (1, 3, 6 month etc). It also provides input boxes where min and max dates can be manually input.
oPrint and Download current graph view - allows the currently data displayed on the graph to be printed or saved (PNG Image, JPEG Image, PDF Document, or SVG Vector Image).
oNavigator - Displays a view of the entire data set. It provides tools to zoom in and out on parts of the data as well as panning across the dataset.
oScrollbar - Offers a means of panning over the X axis of a chart.
| 2) | Status (Real-Time): |
oCurrent RH & Temperature
oCurrent Mode:
▪SmartDRY™
▪SmartBAKE™ – Settings for J-STD or Manual Bake
oEvents:
▪Power ON/OFF
▪Regenerate
▪Recovery
▪Door Activity (Open/Close) - This icon is also displayed on the Data Graph.
▪Door Alarm
▪Temp Alarm Bake
▪RH Alarm Bake
▪Temp Alarm Dry
▪RH Alarm Dry
▪Sensor Fault
▪Dryer Module Fault
▪Bake Heater Fault
|
The Setting are a current snap shot of the cabinet settings. All changes to the cabinet settings have to be done from the Main Display. |
.png)
| 1) | SmartDRY™ Settings: |
oRH - Displays the RH setpoint.
oAlarms - Displays any configured Alarms.
| 2) | SmartBAKE™ Settings: |
oSmartBAKE™ - Displays the settings for baking.
oAlarms - Displays any configured Alarms.
| 3) | Other Settings: |
oDate/Time - Displays the options for the date and time settings.
oData Logging - Displays the log interval when the unit records data.
oSensor - Displays the sensor type, Serial number and configuration.
oDoor Condition - Indicates if the Dashboard displays door notification.
oUnits - Displays the temperature units.
oNetwork - Displays the network IP Address, Subnet Mask and Gate way of the network that the cabinet is connected to.
| 1. | Connect the ECD SmartDRY™ Cabinet to the Network via cable. SmartDRY™ acquires an IP Address from the Network. This will then be the URL Address for the SmartDRY™ Network. |
| 2. | Get IP address assigned by your Network. |
| a. | From the ECD SmartDRY™ Control Panel: |
| i. | Select Menu > Other Settings. |
| ii. | Scroll down to the Network Menu and Press OK. |
| iii. | Log and use the assigned IP address as the web address for your web browser to access SmartDRY™ Network. For example: http://10.1.1.999. |
| 1. | On initial load of your SmartDRY™ Network using your IP address, you’ll be able to view current state of your Cabinet. |
| a. | Graph: |
| i. | Display RH, Temperature, Door Activity Graph. |
| b. | Real Time Status |
| i. | RH, Temperature, Door Activity. |
| ii. | Color Indicators: (Red, Yellow, Green, White) |
| iii. | Events: |
| 1. | Door Open |
| iv. | ECD SmartDRY™ Status and Settings: |
| 1. | SmartDRY™ |
| 2. | SmartBAKE™ |
| v. | Alarms |
| vi. | Fan and Desiccant Indicators. |